Mitsubishi F940GOT-SWD-E Operation Manual page 30

Graphic operation terminals melsec-got
Hide thumbs Also See for F940GOT-SWD-E:
Table of Contents

Advertisement

Graphic Operation Terminal F940GOT
- In the case of host link unit attached to C200H base . . . Setting by each switch
(when C200H-LK201-V1/C200H-LK202-V1 is used)
Setting of switches on front face (common between C200H-LK201-V1 and C200H-LK202-
V1)
Set item
Unit No.
Transmission
speed
Communication
condition
*1 Equivalent to station No. setting in the GOT
Setting of switches on rear face (C200H-LK201-V1)
Set item
Procedure
5 V power supply
CTS changeover
(C200H-LK202-V1)
Set item
Procedure
Connection of termi-
nal resistor
• Cautions
Operation mode of the SYSMAC C Series
When changing the current value and the set value of each device in the C Series PLC, the
PLC should be set to the monitor mode.
If the GOT is connected and the C Series PLC is started up in the running mode, the GOT
sets automatically the PLC to the monitor mode so that the data can be changed.
Mode of PLC at startup
Running mode
Monitor mode
Program mode
Switch setting
SW1
*1
Upper digit BCD
SW2
*1
Lower digit BCD
SW3
6
19200bps
7-bit ASCII and 2 stop bits
SW4
2
Parity: EvenCommand level: 1, 2 or 3
Switch setting
DIP . SW No.3
DIP . SW No.4
Selector switch
Switch setting
Right selector
switch
Left selector
switch
The GOT changes over the PLC from the running mode to the
monitor mode to enable data change.
The PLC remains in the monitor mode, and data change is
enabled.
The PLC remains in the program mode, and data change is
enabled.
Remarks
ON
1:N procedure
OFF
5 V is not supplied.
Up side
External
Lower side
1:N procedure
Up side
Provided
GOT operation
Introduction 1
Remarks
Remarks
1-16