Graphic Operation Terminal F940GOT
u u u u Storage of word device
• Character codes are stored in word devices in the PLC. The stored data is displayed from
the lower 8 bits as shown below.
Example 1
Word Device : D0
Data Length : 1
Bg
(background color)
(The broken line is
not actually
displayed.)
- A character to be displayed at first should be specified using lower 8 bits.
Example 2
Word Device : D0
Data Length : 1
Example 3
Word Device : D0
Data Length : 2 (D0 and D1)
C D
How the data is stored :
Upper bits
D0 (H)
F
D1 (H)
4
n n n n Important point
When the character code is set to "H0" (either for full-width or half-width), characters after that
are not displayed on the screen.
To insert space in a text, store "H8140" (for full-width) or "H20" (for half-width) to the specified
word device.
: When two half-width characters (ASCII codes) are displayed
AB
: When one full-width character is displayed
The required codes (taken from the user defined character set) is :
=F053
The upper and lower two digits of the character
code are reversed.
D0 (H)
: When one full-width character and two half-width characters are displayed
The required ASCII codes (taken from the ASCII code table in the
Appendixes) are :
C
=H43 (one-byte character, 8bit)
=F053 (one-byte character, 8bit)
D
=H44 (one-byte character, 8bit)
Lower bits
0
4
3
2-word
designation
4
5
3
Creation of Display Screen (SW¨ ¨ ¨ ¨ D5C-GOTRE-PACK) 12
From the ASCII code table offered as appendix,
A=H41
ASCII code
B=H42
Data storage status
D0 (H)
4
Upper bits
Lower bits
5
3
F
0
D0 (H)
Upper
Lower
2
4
1
B
A
Upper bits
Lower bits
43
F0
53
44
C
D
12-34