Cable Entries - YOKOGAWA AXG1A Installation Manual

Magnetic flowmeter, size: 25 to 400 mm 1 to 16 in.
Hide thumbs Also See for AXG1A:
Table of Contents

Advertisement

Cable Finish: Finished
(WHITE)
(BLACK)
(RED)
L (Specified Length)
20(0.79)
Length
Specification Code
D
E
AX01C-C 
60 (2.4)
25 (1.0)
70 (2.8)
25 (1.0)
AX01C-B 
70 (2.8)
25 (1.0)
AX01C-D 
Cable Finish: Unfinished
CAP
L (Specified Length) + 340(13.39) (Length for Cable Finish)
Figure 4.2.3 Cable Finish for Signal Cable
CAUTION
• As crimp terminals A, B, SA, SB and C have their
own electrical potentials, securely insulate them so
as not to come in contact with one another.
• To prevent a shield from coming in contact with
another shield or the case, cover each shield with a
vinyl tube or wrap it in vinyl tape.
4.2.3 Recommended Cable for Modbus
communication
3-Wire cable (twisted pair and Common) with shield
should be used.
Wire gauge: AWG24 or wider
Characteristic Impedance of cable: 100Ω or more
4.2.4 Recommended Cable for F
fieldbus communication
Fieldbus type-A specification cable should be used.
Unit: mm (approx. in.)
(WHITE)
(BLACK)
(RED)
F0403.ai
Description
F
G
70 (2.8)
50 (2.0)
For AXW4A
50 (2.0)
60 (2.4)
For AXG1A
50 (2.0)
60 (2.4)
For AXFA11
F404.ai
OUNDATION
<4. Wiring>
4.3

Cable Entries

WARNING
For explosion protection type products, please be sure
to read the user's manual of the applicable explosion
protection type as listed in Table 1.1.
This product is of watertight construction as stipulated in
JIS C 0920. It is shipped with a wiring bracket (waterproof
gland, waterproof gland with union or a
plastic gland attached), only in cases where an optional
specification is selected for the cable entry.
Cable gland has the following kinds depending on the
type and size.
Integral Type Flowmeter
AXW (Size: 25 to 400 mm (1 to 16 in.))
Optional
Description
Code
EG2
2 pcs. of waterproof gland, and a blanking plug
EG3
3 pcs. of waterproof gland
EU2
2 pcs. of waterproof gland with union joint, and a blanking plug
EU3
3 pcs. of waterproof gland with union joint
EP2
2 pcs. of plastic gland, and a blanking plug
EP3
3 pcs. of plastic gland
Remote Sensor
AXW (Size: 25 to 400 mm (1 to 16 in.))
Optional
Description
Code
EW
2 pcs. of waterproof gland with JIS G3/4 female
EG
2 pcs. of waterproof gland
EU
2 pcs. of waterproof gland with union joint
EP
2 pcs. of plastic gland
Remote Transmitter
AXW4A
Optional
Description
Code
EG4
4 pcs. of waterproof gland, and a blanking plug
EG5
5 pcs. of waterproof gland
EU4
4 pcs. of waterproof gland with union joint, and a blanking plug
EU5
5 pcs. of waterproof gland with union joint
EP4
4 pcs. of plastic gland, and a blanking plug
EP5
5 pcs. of plastic gland
Remote Transmitter
AXG1A
Optional
Description
Code
EW5
5 pcs. of waterproof gland with JIS G3/4 female
EG5
5 pcs. of waterproof gland
EU5
5 pcs. of waterproof gland with union joint
EP5
5 pcs. of plastic gland
31
4
IM 01E24A01-01EN

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Axw4aAxw seriesAdmag ti seriesAxfa11gAx01c

Table of Contents