Field Service Ver. 1.1 May 2011
13.3.5
DTMF LEVEL
A. Use
• Dual tone output level.
B. Procedure
• The default setting is -6 dbm.
-2 dbm
-3 dbm
-8 dbm
-9 dbm
-14 dbm
-15 dbm
13.3.6
CNG LEVEL
A. Use
• Calling tone output level.
B. Procedure
• The default setting is -10 dbm.
-2 dbm
-3 dbm
-8 dbm
-9 dbm
-14 dbm
-15 dbm
13.3.7
CED LEVEL
A. Use
• Answer tone output level.
B. Procedure
• The default setting is -10 dbm.
-2 dbm
-3 dbm
-8 dbm
-9 dbm
-14 dbm
-15 dbm
13.3.8
ECM MODE
A. Use
• Select error correction mode.
ON: When an error occurs during communication, re-send the frame where the error
occurs.
OFF: Any error is ignored during communication.
B. Procedure
• The default setting is ON.
-4 dbm
-5 dbm
-10 dbm
-11 dbm
-16 dbm
-17 dbm
-4 dbm
-5 dbm
"-10 dbm" -11 dbm
-16 dbm
-17 dbm
-4 dbm
-5 dbm
"-10 dbm" -11 dbm
-16 dbm
-17 dbm
"ON"
13. SERVICE MODE
"-6 dbm"
-7 dbm
-12 dbm
-13 dbm
-6 dbm
-7 dbm
-12 dbm
-13 dbm
-6 dbm
-7 dbm
-12 dbm
-13 dbm
OFF
131