15. FAX PROTOCOLS

15.4 How to analyze the T30 protocol monitor

• DCS or DIS
• HEX Data as printed on page.
See P.165
• Example: V.17 Communication
NAME: ABC
TEL:886 3 4733507
DATE: APR.23'04 12:20
SESSION
FUNCTION
0001
TX
RING
DATA
ON Time (ms)
1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200 1200
OFF Time (ms)
3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000 3000
TX
RX
• FIF (Facsimile Information Field)
HEX
0
Data Bit
0 0 0 0 0 0 0 0 0
Bit No.
8 7 6 5 4 3 2 1 16 15 14 13 12 11 10 9 24 23 22 21 20 19 18 17 32 31 30 29 28 27 26 25
Bit No.11= 1, Bit No.12=0 7200 bps
Note
Bit No.15= 1 R8 x 7.7 Lines/mm (Fine Mode)
Bit No.19= 0, Bit No.20=1 Unlimited Paper Length
• Hex-Binary Conversion List
Hex
Binary
0
0
0
0
1
0
0
0
2
0
0
1
3
0
0
1
262
PROTOCOL MONITOR REPORT
NO
DESTINATION STATION
ABC
01
22345678901234567890
FF 13 83 00 46 88 00...
FCF (Facsimile Control Field)
= 83: DCS, 80: DIS
Means Last Control Field.
Means address
1
0
4
1
0 0 0 1 1 0 1 0 0 0 1 0 0 0
 
Hex
Binary
0
4
0
1
0
1
5
0
1
0
0
6
0
1
1
1
7
0
1
1
Field Service Ver. 1.1 May 2011
DATE
TIME PAGE DURATION
DEC.02
15:00
008
00h00min00s
DATA
FIF (Facsimile Information Field)
6
8
8
 
Hex
Binary
0
8
1
0
0
1
9
1
0
0
0
A
1
0
1
1
B
1
0
1
MODE
RESULT
ECM-12
OK
2
0
0
0 0 0 0 0 0 0 0
Hex
Binary
0
C
1
1
0
1
D
1
1
0
0
E
1
1
1
1
F
1
1
1
0
1
0
1

Hide quick links: