Soft Switch: #10 - Konica Minolta bizhub C25 Service Manual

Hide thumbs Also See for bizhub C25:
Table of Contents

Advertisement

14. SOFT SWITCH SET
14.3.10

SOFT SWITCH: #10

Bit No.
Designation
Print out RTN page
8
report
Confirmation report
7
result field
6
Get gap time between
digit for pulse dial
5
4
Reserved
Received DIS signal
3
within reception
Transmission time lim-
2
itation
Audio alarm after
1
communication fail
• Bit 8: If this bit set to 1, machine will print out confirmation report after each transaction.
• Bit 7: If this bit set to 1, the result field will show "NG" instead of "OK" in the confirmation
report and activity report or checking the result on the LCD.
• Bit 2: This for manual TX only.
220
Function
0: Not to print
1: Print out RTN page report after transaction for TX/
RX RTN signal
0: Print "OK"
1: Print "NG" in case of sending or receiving RTN signal
Value (ms)
550
Bit No. 6
0
Bit No. 5
0
Reserved
0: Repeat sending DIS/DTC again until time out
1: Disconnected after sending DCN signal
0: No any limitation until document jam
1: Limit to 32 minutes from data phase
0: Not to alarm after transaction fail
1: Alarm after disconnected
Field Service Ver. 1.1 May 2011
650
750
850
0
1
1
1
0
1
Initial
setting
Bit
HEX
1
0
A
1
0
0
0
1
0
1

Hide quick links: