Konica Minolta bizhub C25 Service Manual page 352

Hide thumbs Also See for bizhub C25:
Table of Contents

Advertisement

Field Service Ver. 1.1 May 2011
Code
0047
Can not receive correct signal after sending ERR signal.
0048
Can not receive correct signal after receive PPS_PRI_Q or PRI_Q, EOR_PRI_Q.
0049
Can not receive correct signal after sending PIP/PIN signal within 13 sec.
Line energy over threshold last 60 sec. after MCF, and can not detect FSK or carrier signal
004A
in ECM mode.
004B
Can not detect correct FSK signal even through detected FSK tone within 6 sec.
004C
Handshake fail during re-train or between page in V.34 RX.
004E
Receive DCN signal after sending DIS in V.34.
004F
Remote side disconnected after sending ANSam in V.8 phase.
0050
Can not receive any correct signal after sending CJ signal in V.8 phase.
0051
Can not receive phase 3 signal after phase 2 within 20 seconds in V.34.
0052
Can not receive phase 4 signal after phase 3 within 20 seconds in V.34.
0053
Modem disconnect after phase 4 in V.34.
0054
Remote side disconnected after phase 4 in V.8.
0055
Receive incorrect signal after sending DIS signal in V.34.
0056
Modem disconnect after sending CFR in V.34.
0057
Can not detect image signal within 6 seconds after sending CFR.
0058
Can not detect image signal within 6 seconds after modem enter to primary phase in V.34.
005A
Modem can not detect any correct ECM frame within 3 minutes in phase C.
005B
Can not detect phase 5 signal after primary channel within 6 seconds.
005C
Detect busy tone within control channel after phase C.
005D
Modem can not detect any correct ECM frame within 12 sec. in phase C.
005E
Can not detect control channel signal after received RCP frame within 6 seconds.
005F
Can not detect silence after sending JM signal for polling TX function.
0060
There are no bulletin files to be polled in V.34.
0061
Machine can not detect V.21 or V.8 signal within 35 seconds.
0062
Modem disconnect in phase D after our side sending out flags sequence in control channel.
0063
Can not receive any flag sequence in control channel within 6 seconds in phase D.
Can not detect any control channel signal in phase D within 60 seconds even through
0064
energy still on the line.
0065
Can not detect any control channel signal within 60 seconds after detect silence in phase D.
0066
Can not receive T.30 signal or carrier after sending CFR in V.34.
0070
User press stop key within receiving.
0071
Memory full within receiving.
0072
Received EOR_Q Signal.
Possible Causes of Error.
20. FAX ERROR