18. MALFUNCTION CODE
18.4.32

C013: MAC address error at startup

18.4.33

C015: BOOT ROM error at startup

MFP board/2 (MFPB/2)
Step
1
Reboot the main body.
2
Check the MFPB/1 connector for proper
connection and correct as necessary.
3
Change MFPB/2.
18.4.34

C025: Controller ROM error (Configuration information error)

18.4.35

C026: Controller ROM error (Access error)

18.4.36

C027: Controller ROM error (Data error)

MFP board/2 (MFPB/2)
Step
1
Reboot the main body.
2
Check the MFPB/1 connector for proper
connection and correct as necessary.
3
If this error message is displayed after
update of firmware, conduct the firmware
update procedures again.
4
Change MFPB/2.
18.4.37

C050: HDD access error

MFP board/2 (MFPB/2)
Step
1
Reboot the main body.
2
Check the HDD connector for proper con-
nection and correct as necessary.
3
Check the MFPB/1 connector for proper
connection and correct as necessary.
4
Change HDD.
5
Change MFPB/2.
298
Relevant electrical parts
Action
Relevant electrical parts
Action
Relevant electrical parts
Action
Field Service Ver. 1.1 May 2011
WIRING DIAGRAM
Control signal
-
-
-
WIRING DIAGRAM
Control signal
-
-
-
-
Hard disk kit
WIRING DIAGRAM
Control signal
-
-
-
-
-
Location (electri-
cal component)
-
-
-
Location (electri-
cal component)
-
-
-
-
Location (electri-
cal component)
-
-
-
-
-