Code
0001
Manual receive mode, nothing G3 signal received within 35 sec.
0003
Received DIS after sending DIS signal.
0004
Received DCN after sending DTC signal.
0006
Detect busy tone within receiving phase B.
0009
Can not receive any signal within 35 sec. in manual polling mode.
0010
Received DCN signal after sending DTC signal in polling RX.
0011
Can not receive any correct response after sending three DTC signal.
0012
Remote side password not match in polling RX/our side no any file to be polling.
0013
Can not receive carrier within 6 sec. after sending CFR in data phase C.
0014
Can not receive T.30 signal after sending FTT signal.
0015
Line polarity change within receiving phase B to D.
0016
Receive DCN signal after sending FTT signal.
0017
Can not receive any response from remote side after sending type of xxx_EOM signal.
0018
Can not detect energy within 6 sec. after sending FTT command.
0019
Received DCN signal after sending CFR signal.
001A
No energy on line over 6 sec. within phase C before any corrected ECM frame.
001D
Detect flag but nothing after CFR.
0020
Can not correct frame within 6 sec. or in no-ECM mode, one decoding line over 6 sec.
0021
File full.
Owing to noise interference on the line, receiving side can not receive correct data within
0022
specified time (no ECM).
0023
Received PWD error in RSD or upgrade F/W.
0024
TX and RX machine both are different machine ID in upgrade F/W.
0025
TX and RX machine both are different company ID in upgrade F/W.
0026
Remote monitor level error remote side can not access in upgrade F/W.
002A
Line problem.
0030
Can not receive any signal within 6 sec. at phase D.
0031
Received incorrect signal at phase D (not EOP, MPS, EOM, DCS PPS_Q, PPS_Q, etc.).
0032
Can not receive carrier within 6 sec. after sending MCF or RTP, RTN signal.
0033
Received DCN signal at phase D within pages (not last page).
In non-ECM mode, when machine already received the data but next line data does not
0039
receive within 13.1 seconds.
003F
Remote side TSI not define in machine one touch or speed dial directory.
0040
Can not receive carrier within 6 sec. after sending CTR.
0041
Can not receive carrier within 6 sec. after sending PPR.
0042
Can not receive correct signal after sending RNR signal.
0043
Receive incorrect signal at phase D in ECM mode.
0044
Can not receive carrier /FSK signal within 6 sec. after sending MCF in ECM mode.
0045
Can not receive any correct signal after sending RNR response with ERR signal.
0046
Receive incorrect signal when sending RNR which response with ERR signal.
310
Field Service Ver. 1.1 May 2011
Possible Causes of Error.