Cooling Fan Motor (Fm11) - Konica Minolta bizhub C25 Service Manual

Hide thumbs Also See for bizhub C25:
Table of Contents

Advertisement

Field Service Ver. 1.1 May 2011
7.3.23

Cooling fan motor (FM11)

1. Remove the rear cover.
See P.43
2. Remove the ADF.
See P.98
3. Remove the Scanner unit.
See P.96
4. Remove the front right cover.
See P.45
5. Remove the upper cover.
See P.49
[1]
[4]
[2]
11. To reinstall, reverse the order of removal.
[3]
[2]
A2YFF2C089DA
[1]
A2YFF2C090DA
[1]
[3]
[1]
A2YFF2C091DA
7. OTHER MAINTENANCE ITEM
6. Disconnect the connector [1].
7. Remove the harness [3] from the
wire saddle [2].
8. Remove two screws [1].
9. Remove three screws [1], release
the tab [2], and slide the duct [3].
10. Remove the cooling fan motor [4].
71