Konica Minolta bizhub C25 Service Manual page 370

Hide thumbs Also See for bizhub C25:
Table of Contents

Advertisement

Field Service Ver. 1.1 May 2011
(26) Error code: 00B5
Definition
Can not detect phase 3 signal after phase 2 within 25 seconds.
Solution
1.
2.
3.
4.
(27) Error code: 00B6
Definition
Can not detect phase 4 signal within 25 seconds after CM/JM exchange.
Solution
1.
2.
3.
4.
(28) Error code: 00B7
Definition
Can not detect phase 5 signal after phase 4 within 30 seconds.
Solution
1.
2.
3.
4.
(29) Error code: 00B8
Definition
Remote side disconnect after our side sending DCS signal in V.34.
Solution
1.
2.
3.
4.
(30) Error code: 00B9
Definition
Receive T.30 signal other than DIS, DCS, CFR after sending DCS signal in V.34.
Solution
1.
2.
(31) Error code: 00BC
Definition
Modem can not ready within 10 seconds after entering primary channel in V.34.
Solution
1.
2.
3.
4.
Check the line condition whether is too noisy, if necessary, please replace a new
telephone line or contact your telecom service provider.
Boost the machine TX level. <*1>
Change the machine TX speed to V.17, then resend again.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Check the line condition whether is too noisy, if necessary, please replace a new
telephone line or contact your telecom service provider.
Boost the machine TX level. <*1>
Change the machine TX speed to V.17, then resend again.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Check the line condition whether is too noisy, if necessary, please replace a new
telephone line or contact your telecom service provider.
Boost the machine TX level. <*1>
Change the machine TX speed to V.17, then resend again.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Check the line condition whether is too noisy, if necessary, please replace a new
telephone line or contact your telecom service provider.
Boost the machine TX level. <*1>
Change the machine TX speed to V.17, then resend again.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Change the machine TX speed to V.17, then resend again.
Print out the protocol report, and search for technical support.
Check the line condition whether is too noisy, if necessary, please replace a new
telephone line or contact your telecom service provider.
Boost the machine TX level. <*1>
Change the machine TX speed to V.17, then resend again.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
20. FAX ERROR
329

Hide quick links:

Advertisement

Table of Contents
loading