20. FAX ERROR
(45) Error code: 00D0
Definition

Received ERR signal after sending EOR_NULL.

Solution
1.
(46) Error code: 00D1
Definition
Received incorrect response after sending PPS_EOP signal in V.34.
Solution
1.
2.
(47) Error code: 00D2
Definition
Received DCN after sending PPS_EOP signal.
Solution
1.
(48) Error code: 00D3
Definition

Received DCN after sending PPS_NULL signal.

Solution
1.
(49) Error code: 00D4
Definition

Received DCN after sending PPS_EOM signal.

Solution
1.
(50) Error code: 00D9
Definition
Can not detect correct phase 3 signal after detect silence after phase 2.
Solution
1.
2.
3.
4.
(51) Error code: 00DA
Definition
Can not detect phase 4 signal within 30 seconds or remote side hang up over 6 sec-
onds.
Solution
1.
2.
3.
4.
332
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Change the machine TX speed to V.17, then resend again.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Check the line condition whether is too noisy, if necessary, please replace a new
telephone line or contact your telecom service provider.
Boost the machine TX level. <*1>
Change the machine TX speed to V.17, then resend again.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Check the line condition whether is too noisy, if necessary, please replace a new
telephone line or contact your telecom service provider.
Boost the machine TX level. <*1>
Change the machine TX speed to V.17, then resend again.
Print out the protocol report, and provide it to technical center, ask for analyzing
the information.
Field Service Ver. 1.1 May 2011