HOME
ADU/PAPER EXIT SECTION
[1]
Removing and Reinstalling the Exit
3
Sensor Unit (7020/25/30/35 only)
a. Procedure
(1) Remove the read right cover.
(2) Remove the 2 set screws, and remove the right
side cover (upper).
(3) Remove the 2 set screws, and remove the cover.
(4) Remove the 2 set screws (by inserting the screw-
driver through the holes in the sheet metal). Detach
the connector at the side of the sheet metal, and
remove the exit sensor unit/1.
Connector
Set screws
Cover
Connector
Exit sensor unit/1
(5) Remove the set screw (again, by inserting the
3
screwdriver through the hole), and remove the exit
limit detection actuator.(Old type 7020/25/30/35
only)
(6) Reinstall in the opposite sequence to removal.
Set
screws
3-L-1
ADU/PAPER EXIT SECTION
Set screw
Exit limit detection actuator