Xerox 8825 Service Manual page 172

Hide thumbs Also See for 8825:
Table of Contents

Advertisement

Plug
ESV Channel
Figure 2 Removing the Plug
NOTE: Failure to center the probe will cause incorrect V-LO readings.
NOTE: Run LED Test 9-21.5 to verify that all appropriate LEDs illuminate. Also verify that the
Electrometer probe is located within the center 2 inch (50 mm) wide illuminated section of the
LED bar.
12. Close the Image Module, the Top Cover, and the Front Door.
13. Enter diagnostics.
14. Ensure that V-HI is within specification.
a.
Enter [0921-2] for the check and adjustment.
b.
Turn on the electrometer.
c.
The average meter reading should be
d.
If required, adjust V-HI using the Previous / Next buttons.
e.
Press the Enter button in order to store the value in NVM.
f.
Turn off the electrometer.
15. Ensure that V-LO is within specification.
a.
Enter [0921-3] for the check and adjustment.
b.
Set the Duty Cycle to 15% using the Previous / Next buttons.
c.
Turn on the electrometer.
d.
Record the value on the DMM.
Repairs and Adjustments
ADJ 9.2
Image Module
-600 +15/-5 volts (-585 to -605 volts).
NOTE: In the following step, if no change occurs, ensure that the probe is centered.
e.
Press the Previous button to decrease the Duty Cycle value in 1% increments.
Pause three seconds at each reading until the value changes 10 Volts.
f.
Press the Next button twice to increase the duty cycle value by 2%.
g.
Press the Enter button in order to store the value in NVM.
h.
Turn off the Electrometer.
Table 1 Average Light Output Values
Bar #
Value
1
.75
2
.77
3
.68
4
.74
5
.80
6
.75
7
.74
8
.75
9
.79
10
.61
11
.65
12
.58
13
.71
14
.62
15
.69
16
.70
17
.70
18
.74
19
.71
20
.79
21
.67
22
.92
23
.76
24
.83
25
.79
26
1.05
27
1.05
28
1.05
29
1.10
30
1.13
31
1.02
32
.97
33
1.03
34
1.00
01/02
4-104
8825/8830 Printer