Xerox 8825 Service Manual page 185

Hide thumbs Also See for 8825:
Table of Contents

Advertisement

3.
(
Figure
2): Connect the Temperature Probe to the DMM.
Black Adaptor
Black Jack
Figure 2 Connecting the Temperature Probe to the DMM
4.
Switch on the DMM and then switch on the Temperature Probe.
5.
Set the DMM to measure DC voltage.
6.
Press the 20 Volt range switch on the DMM.
7.
Rotate the select switch of the Temperature Probe to BATT TEST. If the voltage is lower
than 1.7V, replace the battery of the Temperature Probe.
8.
Rotate the select switch of the Temperature Probe to the oº C position and press the
200mV range switch of the DMM.
9.
Enter diagnostics.
10. (
Figure
3): Enter code [ 1004 in order to turn on the Heat Rod and bring the Heat Roll to
the run temperature. The following message is displayed.
Figure 3 Fuser Warm Up Screen
8825/8830 Printer
Red Adaptor
Red Jack
Temperature Probe
01/02
4-117
11. (
Figure
4): Check the bond paper fusing temperature, using the Temperature Probe,
when the following message is displayed.
Figure 4 Fuser Temperature Test Screen
12. Open the Media Transport Latching Cover and press the tip of the Thermal Sensor firmly
to the surface of the Heat Roll
NOTE: As an example, a reading of 143 on the 200mV scale is 143º C (290º F).
13. Press the Exit button three times.
Repairs and Adjustments
ADJ 10.2