Replacement
Do not rotate the Auger Gears individually more than the slight amount required for removal or
to mesh the teeth during reinstallation. If the factory setting of the augers is changed during the
procedure, perform the adjustment procedure, Augers
NOTE: The gears must be reinstalled with the flanges as shown in order to ensure that all the
gears are secured.
1.
(Figure
2): Reinstall the Air Pressure Tubes.
1
Reinstall the Air
Pressure Tube
4
Reinstall the gear
and the Grip Ring
Repairs and Adjustments
REP 9.18
CAUTION
(ADJ
9.6).
Flanges
2
Reinstall the
gear
3
Reinstall the
gear
Figure 2 Reinstalling the Air Pressure Tubes
6
Reinstall the Air
Pressure Tube
5
Retainer
Reinstall the Air
Pressure Tube
01/02
4-80
7
Reinstall the screw
8825/8830 Printer