Rep 9.17 Photoreceptor Seal - Xerox 8825 Service Manual

Hide thumbs Also See for 8825:
Table of Contents

Advertisement

REP 9.17 Photoreceptor Seal

Parts List on
PL 9.5B
Switch off the Main Power Switch. Disconnect the Power Cord.
Removal
1.
Remove the Drum Assembly
(REP
2.
(Figure
1): Remove the Right-hand Seal, the Left-hand Seal (not shown), and the Photo-
receptor Seal.
3.
Thoroughly clean the Photoreceptor Seal channel using a vacuum cleaner.
Replacement
1.
Replace the Photoreceptor Seal.
a.
Carefully fold the Photoreceptor Seal along the perforations.
b.
Slide the Photoreceptor Seal into the channel, smaller side up, so that the edge of
the Photoreceptor Seal forms a seal with the inside lip of the channel.
c.
Using a soft, straight tool (a piece of shimstock works well), carefully push the seal
into the channel, across the entire width of the Xerographic Module.
2.
Reinstall the Right-hand Seal.
a.
Insert the red stripe end of the Right-hand Seal underneath the fold of the Photore-
ceptor Seal.
b.
Install the seal fuzzy side up.
c.
Ensure that the seal is flush against the Xerographic Module Frame.
3.
Reinstall the Left-hand Seal in the same manner.
Repairs and Adjustments
REP 9.17
WARNING
9.2).
Photoreceptor
Seal Channel
Photoreceptor
Right-hand
Seal
Seal
Cleaner Blade
Figure 1 Removing and Replacing the Photoreceptor Seal
01/02
4-78
Xerographic Module
Frame
Blade Retainer (3)
8825/8830 Printer

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

8830

Table of Contents