PQ 17 Smears

Table 1 Smears Symptom / Check
Symptom/ check
Location of Smear Probable Cause
Areas of the image on the
print are
blurred.
This
occurs at the image transfer
area and is caused by a dif-
ference of speed between
the drum and the media.
20 - 25 mm from the
Lead Edge of the
print
40 - 50 mm from the
Lead Edge of the
print
106 - 126 mm from
the Lead Edge of
the print
150 - 170 mm from
the Lead Edge of
the print
140 - 160 mm from
the
Trail Edge of
the print
66 - 86 mm from the
Trail Edge of the
print (Register Roll
Exit Smear)
Random smears
8825/8830 Printer
Corrective Action
Transfer/Detack
Check / replace (
Shield incorrectly
PL
9.4)
installed.
Fabric Guide worn,
Check / replace (
contaminated
or
REP
8.9).
incorrectly installed.
1.
Worn (smooth)
Check / replace (
Heat Roll (
PL
10.2)
REP
10.2)
2.
Worn Contami-
Check / replace (
nated Fabric Guide
REP
8.9)
(
PL
10.3)
3.
Check / replace
3. Pressure Plate A
(
REP
8.5)
installed incorrectly
or deformed (
PL
10.3).
Pressure Plate B
Check / replace (
installed incorrectly
REP
8.5)
or deformed.
Cutter
Check
for
loose
Cutter Drive Pulley,
Shim / replace (
PL
7.8)
Buckle Switch
Enter
[8-2
and
check
for
correct
operation (
PL
8.4)
Media Transport
Ensure
that
the
Media
Transport
gap (
ADJ
8.4) is set
correctly.

PQ 17A Smudge

Table 1 Smudge Symptom / Check
Symptom/ check
Location
A smudge is a displacement
Smudge
of the toner image on the
drum or the media.
Perform
GP
2, Image on
Media
Drum to determine if the
Smudge
occurs
on
the
media or the drum.
Media
Media
Media
Media
Vellum Smudge is a special
Combination of Vellum beam strength
defect that exhibits marginal
and low Heat Roll drive force.
fusing fix. Toner can chip off
media is flexible enough that it buckles
of the media and horizontal
between Pressure Plates A and B. The
lines are broken (image dis-
toner then melts and partially sticks to the
placement).
Heat Roll. As the media enters the Pres-
sure Plate B, it flattens and the image is
displaced in front of it's correct position.
The toner can also become a clump on
the media and easily chip off of the
media.)
Drum
Drum
01/02
3-17
of
Probable Cause
Corrective Action
Heat Roll
Check for a worn
(smooth) Heat Roll.
Replace
(
10.2)
Fabric Guide
Check for a worn /
contaminated Fab-
ric Guide. (
8.9)
Excessive
media
Ask the customer to
curl
(smudge
replace the media.
appears 100 mm
from lead or trail
edge)
Detack Corotron
Check for contami-
nation or signs of
arcing.
Clean /
replace (
PL
9.4)
Buckle Switch
Check the Buckle
Switch for correct
operation (
PL
8.4)
Replace the Fabric
(The
Guide (
REP
8.9)
and the Heat Roll (
REP
10.2).
Mechanical interfer-
Check for interfer-
ence with the image
ence.
on the drum
Buildup of devel-
Push excess devel-
oper material on the
oper material back
lower extrusion of
into the housing.
the developer hous-
ing
rubbing
the
developed
image
on the drum.
Print Quality
PQ 17, PQ 17A
REP
REP