2): Adjust the Toner Cartridge Home Sensor to 2.5 ± 0.5 mm from the plate.
2.
(
Figure
3
Straighten the wires and adjust the
sensor
2
Remove the wires
from the clamps (2
places)
Repairs and Adjustments
ADJ 9.5
1
Disconnect Q2
Figure 2 Adjusting the Toner Cartridge Home Sensor
01/02
4-114
2.5 +/- 0.5 mm