a.
Insert the red stripe end of the Left-hand Seal underneath the folded Photoreceptor
Seal.
b.
Install the seal fuzzy side up.
c.
Ensure that the seal is flush against the Xerographic Module Frame.
7.
Perform
GP 4
Drum Cleaning Enhancement procedure.
8825/8830 Printer
Xerographic Module
Frame
Cleaner Blade
Figure 3 Installing the Cleaner Blade Kit
01/02
4-53
Left-hand Seal
Photoreceptor
Seal
Blade Retainer (3)
Repairs and Adjustments
REP 9.4