7
7.1
Description
GSI coding
Access
Coding
Coding
Standard Coding
Codes contain information about recorded points. With the help of coding, points can
be assigned to a particular group simplifying later processing.
Codes are stored in codelists, with each codelist supporting a maximum of 200 codes.
Codes are always stored as free codes (WI41-49), that means that codes are not
directly linked to a point. They are stored before or after the measurement
depending on the setting made. Point codes (WI71-79) are not available.
A code is always recorded for each measurement as long as the code is displayed in
the Code: field. For a code not to be recorded, the Code: field must be cleared. This
can be set to occur automatically. Refer to "4.1 General Settings".
•
Either, select Q-Survey from the MAIN MENU and press
•
Or, press FNC when within any application and select Free Coding.
CODE.