Leica FlexLine TS02 User Manual page 278

Hide thumbs Also See for FlexLine TS02:
Table of Contents

Advertisement

Technical Data
Accuracy
Characteristics
Accuracy refers to measurements to standard reflectors.
EDM measuring mode Standard deviation ISO 17123-4 Measurement
Prism-Standard
Prism-Fast
Prism-Tracking
Tape
Beam interruptions, severe heat shimmer and moving objects within the beam path
can result in deviations of the specified accuracy.
Principle:
Type:
Carrier wave:
Measuring system:
/
1.5 mm + 2 ppm
1 mm + 1.5 ppm 2.4
3 mm + 2 ppm
3 mm + 1.5 ppm 0.8
3 mm + 2 ppm
3 mm + 1.5 ppm <0.15
5 mm + 2 ppm
5 mm + 1.5 ppm 2.4
Phase measurement
Coaxial, visible red laser
658 nm
System analyser basis 100 MHz - 150 MHz
FlexLine, 278
time, typical [s]