Accuracy Results
Applications
Sight the target point and select ALL, or DIST and REC to measure to the target
point.
Next step
Either, press F1 or F2 to continue measurements.
Or, press F4 Compute to calculate the station position and orientation.
If a target point is measured several times in the same face, only the last valid
measurement is used for computation.
For the calculation of the station position, measured target points can be re-
measured, included in calculations, or excluded from calculations.
F1 Measure more points
To return to the Enter target data
screen to measure more points.
F2 Measure in other face
To measure the same target point in
another face.
F3 Access acc. limits
To change the accuracy limit values.
F4 Compute
To calculate and display the station
coordinates.
FlexLine, 103