Leica FlexLine TS02 User Manual page 202

Hide thumbs Also See for FlexLine TS02:
Table of Contents

Advertisement

Applications
Traverse
configuration
It is not recommended to start a traverse if the memory is almost full. Doing so, may
mean the traverse measurements and results cannot be saved. Accordingly, a
message is displayed if less than 10% of the memory is free.
Field
Description
Traverse ID
Name of the new traverse.
Descr
Description, if desired.
Operator
Name of the user who will be using the new traverse, if desired.
Method
B'F'F''B'' All points are measured in face I, then all points are
B'B''F''F' The backsight point is measured in face I immediately
B'F'
Nr. of Sets
Number of sets. Limited to 10.
Use Face-Tol Important when measuring with face I and II. This checks if both
measurements are within a defined limit. If the limit is exceeded, a
warning message is displayed.
Face Tol.
The limit that will be used for checking the face tolerance.
measured in face II in reverse sequential order.
followed by face II. Other points are measured in
alternating face order.
All points are measured in face I only.