Applications
Field
Description
Height
Calculated Height coordinate of the station.
Hz
Current Hz angle with the new orientation.
Δ
Available for Method: Height Transfer or Ori. with Coord. with only
1 target point. Difference between the calculated and measured
HorizD from the station to the design target.
Accur.Posi
If the standard deviation for position in E and N is calculated, a
tion
checkbox is displayed. The checkbox is checked if the calculated
position is within the standard deviation limits or crossed if it is not.
Accur.Heig
If the standard deviation for Height is calculated, a checkbox is
ht H
displayed. The checkbox is checked if the calculated Height is within
the standard deviation limits or crossed if it is not.
Accur.Hz
If the standard deviation for the Hz Orientation angle is calculated, a
Ori.
checkbox is displayed. The checkbox is checked if the calculated Hz
Orientation is within the standard deviation limits or crossed if it is not.
Remark
Description of the station if entered by the user.
Δ Ori.Corr. Hz orientation correction between the old and the new North
direction.
Scale
Available for Method: Resection. The calculated scale, if available.