Leica FlexLine TS02 User Manual page 107

Hide thumbs Also See for FlexLine TS02:
Table of Contents

Advertisement

Target Residuals
Messages
Applications
Field
Description
Apply
Yes or No. Select Yes to use the calculated scale as the system PPM
Scale
scale. This overwrites any PPM scale previously set in the EDM Settings
screens. Select No to keep the existing PPM value in the system and
not apply the calculated scale.
Next step
Press RESID to display the target residuals.
The TARGET RESIDUALS screen displays the computed residuals for the horizontal
and vertical distances and the horizontal direction. Residual = Calculated value -
Measured value.
The following are important messages or warnings that may appear.
Messages
Selected point has no
valid data!
Max 10 points
supported!
Invalid data - no
position computed!
Description
This message occurs if the selected target point has no
Easting or Northing coordinate.
10 points have already been measured and another point
is selected. The system supports a maximum of 10 points.
The measurements may not allow final station
coordinates (Eastings, Northings) to be computed.
FlexLine, 107