FRU Disassembly
Low Voltage Power Supply (LVPS) (P4510)
8-64
(PL12.1.5)
1. Exit motor PWBA
2. LVPS
Procedure:
1.
Remove the front cover (page 8-11).
2.
Remove the LVPS shield plate (page 8-60).
Caution
Do not attempt to unplug the cable from J101 on the LVPS. This is a
soldered connection and attempts to disconnect the wire will damage
the circuit board.
1
3
P42
P43
J101
P44
P45
P41
P47
P48
3. P101
Phaser 4500/4510 Service Manual
2
P46
P40
P504
s4510-144