Theory of Operation
2-24
Fuser Warm-Up
The halogen lamp is turned on when the fuser warm-up begins. When the
surface temperature of the heat roller (detected by the thermistor) reaches the
fuser control temperature (standby temperature), the fuser warm-up is ended.
Fuser Temperature Cycling
The fuser temperature does not remain at a single, constant value, but varies
within a temperature range. There are several ranges, which are summarized
in the table. Except for Standby, the setting is determined by the media type
selection.
Phaser 4500 Fuser Cycling Temperatures
Setting
Standby
Medium
High
Extra High
Low
Phaser 4510 Fuser Cycling Temperatures
Setting
Standby
Low
Medium
High
Very High
Extra High
Very Low
Temperature
Lamp ON 180° C
Lamp OFF 185° C
1-100 pages:
101-120 pages:
Lamp ON 205° C
Lamp ON 205° C
Lamp OFF 206° C
Temp. decreases
by.25° C per page
Lamp ON 210° C
Lamp OFF 211° C
Lamp ON 215° C
Lamp OFF 216° C
Lamp ON 185° C
Lamp OFF 186° C
Temperature
Lamp ON 180° C
Lamp OFF 185° C
1-50 pages:
51-62 pages:
Lamp ON 190° C
Lamp ON 190° C
Lamp OFF 191° C
Temp. decreases by
.25° C per page
1-50 pages:
51-70 pages:
Lamp ON 210° C
Lamp ON 210° C
Lamp OFF 211° C
Temp. decreases by
.25° C per page
Lamp ON 212° C
Lamp OFF 213° C
Lamp ON 214° C
Lamp OFF 215° C
Lamp ON 187° C
Lamp OFF 188° C
Lamp ON 185° C
Lamp OFF 186° C
120 + pages:
Lamp ON 200° C
Lamp OFF 201° C
63 + pages:
Lamp ON 187° C
Lamp OFF 188° C
71 + pages:
Lamp ON 205° C
Lamp OFF 206° C
Phaser 4500/4510 Service Manual