FRU Disassembly
Offset Motor Assembly
8-120
Replacement Notes:
Be sure to install the stacker PWBA into the two guide slots of the stacker.
Be sure that the flag on the stack full actuator is in the gap in the sensor
on the stacker PWBA.
(PL23.1.20)
1. Offset motor assembly
Procedure:
1.
Remove the stacker PWBA (page 8-119).
2.
Remove the two 8 mm tapping screws that attach the offset motor
assembly to the stacker.
3.
Remove the offset motor assembly.
1
Phaser 4500/4510 Service Manual
s4500-209