FRU Disassembly
Low Voltage Power Supply (LVPS) (P4500)
8-62
(PL12.1.5)
1. Exit motor PWBA
2. LVPS
Procedure:
1.
Remove the front cover (page 8-11).
2.
Remove the LVPS shield plate (page 8-60).
Caution
Do not attempt to unplug the cables from J101 or J104 on the LVPS.
These are soldered connections and attempts to disconnect the wires
will damage the circuit board.
1
3
4
P/J 42 41 40
P/J
43
44
45
46
47
48
3. P101
4. P/J404
Phaser 4500/4510 Service Manual
2
s4500-144