Duplex Unit Motor
Phaser 4500/4510 Service Manual
(PL21.1.29)
1. Duplex unit motor
2. Ground wire
3. Motor bracket
Procedure:
1.
Remove the left cover (page 8-96).
2.
Remove the 6 mm screw that attaches the duplex unit assembly harness
ground
3.
Remove the three 8 mm tapping screws that attach the motor bracket to
the duplex unit housing cover.
4.
Remove the screw that mounts the duplex unit PWBA to the motor
bracket.
5.
Remove the latch spring.
1
2
3
4
FRU Disassembly
5
4. Latch spring
5. Duplex unit housing cover
s4510-195