1946
Press FB Stop: Target Temp Diff
This SP calculates the hot roller target temperature while pressure roller
feedback control is stopped. This SP determines the target hot roller temperature
while pressure roller feedback control is not operating. The temperature is
determined based on the paper type and length of the paper (Length Level).
Note: The Length Levels (1 to 5) are defined by SP1945.
1 Length Level 1: Normal
2 Length Level 2: Normal
3 Length Level 3: Normal
4 Length Level 4: Normal
5 Length Level 5: Normal
11 Length Level 1: Cold Start
12 Length Level 2: Cold Start
13 Length Level 3: Cold Start
14 Length Level 4: Cold Start
15 Length Level 5: Cold Start
16 Length Level 0: Cold Start
1947
Press FB Stop: Time Period
This SP sets the length of time that pressure roller feedback is suspended for the
paper lengths defined by SP1945.
Pressure roller feedback control begins when the time set with this SP has
elapsed after paper feed starts.
As more paper is fed for a multiple print job, the time setting for succeeding
sheets is overwritten.
However, for succeeding sheets where the time prescribed for feedback
suspension is "0", the "0" value is not overwritten, but feedback suspension
control is maintained until countdown for the multiple copies is finished.
SM Appendix
o
[0 to 30/15/1
C]
o
[0 to 30/10/1
C]
o
[0 to 30/7/1
C]
o
[0 to 30/5/1
C]
o
[0 to 30/3/1
C]
o
[0 to 30/10/1
C]
o
[0 to 30/5/1
C]
o
[0 to 30/3/1
C]
o
[0 to 30/0/1
C]
2-33
SP1-xxx Feed
D093/D094