MF Error Counter Japan Only
7826
Displays the number of counts requested of the card/key counter.
1 Error Total
A request for the count total failed at power on. This error will occur if the
device is installed but disconnected.
2 Error Staple
The request for a staple count failed at power on. This error will occur if the
device is installed but disconnected.
MF Error Counter Clear
7827
Press [Execute] to reset the values of SP7826 to "0". Japan Only
Self-Diagnosis Result Display
Opens the "Self-Diagnose Result Display" to view details about errors. Use the
7832
keys on in the display to scroll through all the information. If no errors have
occurred, you will see "No Error".
Total Memory Size
7836
Displays the memory capacity of the controller system: "1024 MB".
7901
Assert Info.
This SP displays the results of the last occurrence of SC990. SC990 is issued
when unexpected branching and decision data is generated by the program, and
the module name, line number, and values for the error are displayed for
analysis. This data should be reported after SC990 occurs.
1 File Name
2 Number of Lines
SM
CTL
CTL
CTL
CTL
Module name
Lines where error occurred.
6-105
Main SP Modes
D093/D094