Lower Limit Temp: Hot Roller - Ricoh D093 Service Manual

Table of Contents

Advertisement

1934

Lower Limit Temp: Hot Roller

This SP sets the minimum difference in temperature allowed between the
actual temperature and the target temperature of the hot roller.
Important: Modes "1" to "5" below refer to the paper and thickness settings
selected in User Tools (see "Paper Thickness Default Selection" in this
section).
1 Plain: Mode1
2 Plain: Mode2
3 Plain: Mode3
4 Plain: Mode4
5 Plain: Mode5
6 Trans.: Mode1
7 Trans.: Mode2
8 Trans.: Mode3
9 Trans.: Mode4
10 Trans.: Mode5
11 Film: Mode1
12 Film: Mode2
13 Film: Mode3
14 Film: Mode4
15 Film: Mode5
16 Plain: Low Temp Mode
SM
[0 to 50/20/5]
[0 to 50/15/5]
[0 to 50/25/5]
[0 to 50/20/5]
[0 to 50/0/5]