2401
Separation Current Timing
This SP controls the timing of the application of the voltage that separates the
paper from the drum after the toner image has been transferred from the drum to
the paper.
Notes:
This adjustment can be done only for the standard feed sources (roll or
cassette). The adjustment cannot be done for paper fed from the manual
feed tray.
Independent adjustments for the type of paper (plain, translucent, film)
cannot be done.
Both AC and DC voltages are applied. The applied AC voltage remains
constant. Only the level of the applied DC voltage can be adjusted.
Both AC/DC voltages switch on at [A].
The level of the DC voltage switches to a lower level [B] and causes the total amount of
applied voltage to drop.
Both AC/DC voltages switch off at [C].
The AC level remains constant. Only the DC level is switched to a lower voltage at [B].
SM Appendix
2-49
SP2-xxx Drum
D093/D094