SP4-xxx Scanner
4733
LED Adjustment DFU
The following SP codes displays LAMPR OFF setting of each CIS element
analog ASIC (LM98714) after RGB white level adjustment when the machine is
powered on.
The peak value for standard white plate reading (the shading data peak
value) is set to 880 ±20 digits by Red white level adjustment.
The setting can be written with this SP and the set value is reflected in the
analog ASIC (LM98174) of the CIS when an original is scanned.
[23 to 523 / 304 / 1]
1 CIS 1 R
2 CIS 2 R
3 CIS 3 R
4 CIS 4 R
5 CIS 5 R
6 CIS 1 G
7 CIS 2 G
8 CIS 3 G
9 CIS 4 G
10 CIS 5 G
11 CIS 1 B
12 CIS 2 B
13 CIS 3 B
14 CIS 4 B
15 CIS 5 B
D093/D094
2-88
SM Appendix