4. PREVENTIVE MAINTENANCE
4.1 PM TABLES
Key for the PM Table
A = Adjust, C = Clean, I = Inspect, L = Lubricate, R = Replace
Units of measure in the PM Interval column: Metric: 1,000 meters, Feet: 1,000 feet
4.1.1 MAIN MACHINE (D093/D094)
Description
Scanner
Original Feed Rollers
Original Exit Rollers
Platen White Plate
Original Width, Set,
Registration, Exit Sensors
Exposure Glass
CIS Surfaces
Development
Developer (1000 g)
Development Filter
Development Roller Gear
SM
PM Interval
Q'ty
Metric
Feet
5.5
18.0
5.5
18.0
5.5
18.0
33.0
108.0
5.5
18.0
5.5
18.0
2
27.5
90.0
5.5
18.0
5.5
18.0
4-1
PM
Comments
C
Damp cloth
C
C
C
Blower brush
C
Damp cloth or glass
cleaner
C
Alcohol or lens paper
R
Replace if necessary.
(
p.5-41)
C
Dry cloth or vacuum
cleaner
I
PM Tables