Upper Limit Temperature: Press Roller - Ricoh D093 Service Manual

Table of Contents

Advertisement

Main SP Modes
1935

Upper Limit Temperature: Press Roller

This SP changes the stepped adjustments of SP1932 (Target Temp: Pressure
Roller) by using the sum of the settings of SP1932 (Target Temp: Pressure
Roller) +SP1935 (Press FB Control Steps) as the steps.
Example
If the pressure roller temperature for SP1935-1 is 100oC, the target hot
roller temperature is 195oC ("100" is SP1932, "195" is SP1931).
If the pressure roller temperature 120oC (= "100"+"20", this is
SP1932+SP1935), the target hot roller temperature is 175oC (="195"-"20",
this is SP1931 – SP1934)
If the setting is "0", the temperature settings of SP1931 do not change.
1 Plain: Mode1
2 Plain: Mode2
3 Plain: Mode3
4 Plain: Mode4
5 Plain: Mode5
6 Trans.: Mode1
7 Trans.: Mode2
8 Trans.: Mode3
9 Trans.: Mode4
10 Trans.: Mode5
11 Film: Mode1
12 Film: Mode2
13 Film: Mode3
14 Film: Mode4
15 Film: Mode5
16 Plain: Low temp. Mode
D093/D094
[0 to 50/20/5]
[0 to 50/25/5]
[0 to 50/30/5]
[0 to 50/20/5]
[0 to 50/0/5]
6-12
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

D094