Target Temp: Hot Roller

Sets the target fusing temperature of the hot roller. After you adjust these SP's,
you must switch the main power switch off and on.
Important: Modes "1" to "5" below refer to the paper type and thickness
settings selected in User Tools (see "Paper Thickness Default Selection" in this
section).
1 Plain: Mode1
2 Plain: Mode2
3 Plain: Mode3
4 Plain: Mode4
5 Plain: Mode5
6 Trans.: Mode1
7 Trans.: Mode2
8 Trans.: Mode3
9 Trans.: Mode4
10 Trans.: Mode5
11 Film: Mode1
12 Film: Mode2
13 Film: Mode3
14 Film: Mode4
15 Film: Mode5
16 Plain: Low Temp Mode
SM
o
[120 to 220/195/5
o
[120 to 220/185/5
o
[120 to 220/175/5
o
[120 to 220/205/5
o
[120 to 220/195/5
o
[120 to 220/165/5
o
[120 to 220/165/5
o
[120 to 220/195/5
o
[120 to 220/190/5
o
[120 to 220/185/5
o
[120 to 220/175/5
o
[120 to 220/195/5
6-9
Main SP Modes
C]
C]
C]
C]
C]
C]
C]
C]
C]
C]
C]
C]
D093/D094