3.1.3 MACHINE LEVEL

1.
Front to back: Not more than 5 mm from level
2.
Right to left: Not more than 0.15/1000 mm from level.

3.1.4 POWER SOURCE

This machine is provided with a circuit breaker that cuts the power supply to the main
machine in case of a current overload or short circuit. The machine must be installed in
a building where circuit breakers (and equivalent devices) can operate properly.
1.
Input Voltage Level:
120V, 60 Hz, 15A or more
220-240V, 50/60 Hz, 10A or more
2.
Permissible Voltage Fluctuation: ±10%
3.
Do not set objects on the power cord.
Make sure the plug is firmly inserted in the outlet.
Do not connect the machine to a power source that is shared with other equipment.
To prevent damage to the breaker switch, installation of a voltage stabilizer (constant
voltage transformer) is recommended for work sites where there is fluctuation in the AC
power source.
To protect the HDD, always switch the machine off with the operation switch on the
operation panel, wait for the power switch LED to stop flashing, then switch off the
main switch on the side of the machine.