Panasonic KX-NCP500 Programming Manual page 267

Pure ip-pbx
Hide thumbs Also See for KX-NCP500:
Table of Contents

Advertisement

Value Range
0–3000 ´ 100 ms
Maintenance Console Location
3.32 [1-1] Slot—Card Property - PRI type
Programming Manual References
None
Feature Manual References
None
ISDN Extension—T306
Specifies the maximum time that the PBX waits for a reply after sending the DISC (disconnection) message
to ISDN. This setting is used when inband tones are supplied.
Default
300 ´ 100 ms
Value Range
0–3000 ´ 100 ms
Maintenance Console Location
3.32 [1-1] Slot—Card Property - PRI type
Programming Manual References
None
Feature Manual References
None
ISDN Extension—T307
Specifies the maximum time that the PBX maintains a suspended call, before restarting.
Default
1800 ´ 100 ms
Value Range
0–6000 ´ 100 ms
Maintenance Console Location
3.32 [1-1] Slot—Card Property - PRI type
Document Version 2011-10
3.32 [1-1] Slot—Card Property - PRI type