Maintenance Console Location
3.29 [1-1] Slot—Card Property - LCO type
Programming Manual References
None
Feature Manual References
None
Low Speed Pulse Dial—Pulse % Break
Specifies the % break for a low speed pulse dial. This is the ratio between the break (on-hook) signal and make
(off-hook) signal in a pulse dial.
Default
60 %
Value Range
Other, 60 %, 67 %
Maintenance Console Location
3.29 [1-1] Slot—Card Property - LCO type
Programming Manual References
3.30 [1-1] Slot—Port Property - LCO Port
Feature Manual References
None
Low Speed Pulse Dial—Break Width
Specifies the maximum length of the break signal in a low speed pulse dial.
% Break on this screen determines the value that can be specified here.
Default
60 ms
Value Range
4 ´ n (n=6–20) ms
Maintenance Console Location
3.29 [1-1] Slot—Card Property - LCO type
Programming Manual References
3.30 [1-1] Slot—Port Property - LCO Port
Document Version 2011-10
3.29 [1-1] Slot—Card Property - LCO type
Low Speed Pulse Dial—Pulse
PC Programming Manual
241