Maintenance Console Location
3.11 [1-1] Slot—Shelf Property - Virtual IP Gateway—GW Settings
Programming Manual References
None
Feature Manual References
None
IP Codec Priority—1st, 2nd, 3rd
Specifies the priority of the codecs to be used. For fax communications, it is necessary to specify G.711A or
G.711Mu for 1st priority.
Default
1st: G.729A
2nd: None
3rd: None
Value Range
For 1st:
G.711A, G.711Mu, G.729A
For 2nd and 3rd:
None, G.711A, G.711Mu, G.729A
Maintenance Console Location
3.11 [1-1] Slot—Shelf Property - Virtual IP Gateway—GW Settings
Programming Manual References
None
Feature Manual References
None
Packet Sampling Time (G.711A)
Specifies the time interval between measurements (samples) of sound data during a conversation. The smaller
this number, the higher the quality of the transmitted sound.
Default
20 ms
Value Range
10 ms, 20 ms, 30 ms, 40 ms, 50 ms, 60 ms