Panasonic KX-NCP500 Programming Manual page 492

Pure ip-pbx
Hide thumbs Also See for KX-NCP500:
Table of Contents

Advertisement

4.18 [2-9] System Options
Maintenance Console Location
4.18 [2-9] System Options
Programming Manual References
None
Feature Manual References
3.1.24 CTI (Computer Telephony Integration)
3rd Party CTI—System status retry counter
Specifies the number of times that the alive check is repeated for Third Party Call Control CTI. When the alive
check has been attempted the programmed number of times without success, the PBX assumes that the logical
connection with the CTI application software has been lost.
Default
5
Value Range
0–10
Maintenance Console Location
4.18 [2-9] System Options
Programming Manual References
None
Feature Manual References
3.1.24 CTI (Computer Telephony Integration)
3rd Party CTI—CDR retry interval timer
Specifies the length of time until the alive check of CDR is retried when no response is received, for Third Party
Call Control CTI.
Default
20 s
Value Range
0–60 s
Maintenance Console Location
4.18 [2-9] System Options
492