Messages - Cisco D9054 Installation And Operation Manual

Hdtv encoder
Table of Contents

Advertisement

Messages

General
The status of the D9054 HD Encoder and its immediate surroundings is reported to
ROSA in the form of messages and alarms. In ROSA you can enable or disable
messages and attach an alarm category to each message.
Before You Start
If you have a ROSA system, messages from the D9054 HD Encoder are shown in the
Copernicus Server Explorer tree.
You define and set up the status of the messages from the Message Settings page in
the D9054 HD Encoder GUI.
D9054 HD Encoder Message List
The following shows an alphabetical list of the available messages, their default
status and an explanation to the messages.
AAC wer Supply Replacement
Message
Description and Remedy
Description: The encoder failed to lock to
AAC: Audio
the audio frame or the audio sample
input loss
frequency is out of range.
Remedy: Check the cable and the
incoming signal.
Description: The encoding rate is too high
AAC: TS rate/
compared to the TS rate or the encoding
Audio rate
rate is too low. The encoding will restart.
mismatch
Remedy: Check the settings. Change the
encoding rate or increase the TS rate. If a
FIFO occurs recurrently, contact the
closest Cisco customer support center for
assistance.
Description: It is not possible to
AAC: Audio
implement the requested audio delay.
delay error
Remedy: Decrease the audio data rate or
change the video settings to decrease the
end-to-end delay. Check the relative and
external delay settings.