www.ti.com
4.17 JTAG Timing Requirements Over Recommended Operating Conditions
PARAMETER
t
TCK period
period
t
TDI/TMS/TRST_N setup to ↑ TCK
setup
t
TDI/TMS/TRST_N hold from ↑ TCK
hold
T
TDO delay from TCK falling
valid
(1) Unless otherwise noted.
TCK
TDI/TMS/
TRST_N
Copyright © 2007–2009, Texas Instruments Incorporated
TEST CONDITIONS
See
Figure
4-15.
See
Figure
4-15.
See
Figure
4-15.
See
Figure
4-15.
t
PERIOD
t
SETUP
t
VALID
TDO
Figure 4-15. JTAG Timing
Submit Documentation Feedback
Product Folder Link(s):
SLLS838F – MAY 2007 – REVISED DECEMBER 2009
MIN
66.67
3
5
0
t
HOLD
TLK3134
TLK3134
(1)
NOM
MAX
UNIT
ns
ns
ns
5
ns
Electrical Specifications
125