2.

Absolute Maximum Ratings

The absolute maximum ratings given Table 1 should under no circumstances be violated.
Stress exceeding one or more of the limiting values may cause permanent damage to the
device.
Parameter
Supply voltage, VDD
Voltage on any pin
Input RF level
Storage temperature range
Package body temperature
Humidity non-condensing
ESD
(Human Body Model)
1
The reflow peak soldering temperature (body temperature) is specified according to
IPC/JEDEC J-STD_020D "Moisture/Reflow Sensitivity Classification for Nonhermetic Solid
State Surface Mount Devices".
Caution! ESD sensitive device.
Precaution should be used when handling
the device in order to prevent permanent
damage.
3.

Operating Conditions

The operating conditions for
Parameter
RF Frequency Range
Operating ambient temperature range
Supply voltage
4.

Electrical Specifications

Table 3 to Table 10 gives the
performed using the 2 layer PCB CC1020EMX reference design. This is the same test circuit
as shown in Figure 3. Temperature = 25°C, supply voltage = AVDD = DVDD = 3.0 V if
nothing else stated. Crystal frequency = 14.7456 MHz.
The electrical specifications given for 868 MHz are also applicable for the 902 - 928 MHz
frequency range.
Min
Max
-0.3
5.0
-0.3
VDD+0.3, max 5.0
10
-50
150
260
5
85
±1
±0.4
Table 1. Absolute maximum ratings
CC 020
1
are listed in Table 2.
Min
Typ
402
804
-40
2.3
3.0
Table 2. Operating conditions
CC1020
electrical specifications. All measurements were
SWRS046B
Unit
V
All supply pins must have the
same voltage
V
dBm
°C
°C
Norm: IPC/JEDEC J-STD-020D
%
kV
All pads except RF
kV
RF Pads
Max
Unit
Condition / Note
470
MHz
Programmable in <300 Hz steps
940
MHz
Programmable in <600 Hz steps
85
°C
3.6
V
The same supply voltage should
be used for digital (DVDD) and
analog (AVDD) power.
A 3.0 ±0.1 V supply is
recommended to meet the ARIB
STD T-67 selectivity and output
power tolerance requirements.
CC1020
Condition
1
Page 5 of 91