2.8

Programmers Reference

2.8.1 10G XAUI Programmers Reference (ST = 0)
Following 10G XAUI registers can be addressed only through Clause 45. Primary device input pin "ST"
must be 0 to use Clause 45.
ADDRESS: 0x0000
BIT(s)
NAME
4/5.0.15
Reset
4/5.0.14
Loop Back
4/5.0.13
Speed Selection
4/5.0.11
Low Power
4/5.0.6
Speed Selection
4/5.0.5:2
Speed Selection
(1) In this section XS refers to either PHY or DTE XS device.
(2) RO: Read-Only, RW: Read-Write, SC: Self-Clearing, LL: Latching-Low, LH: Latching-High, COR: Clear-on-Read
ADDRESS: 0x0001
BIT(s)
NAME
4/5.1.7
Fault
XS Transmit Link
4/5.1.2
Status
4/5.1.1
Low Power Ability
ADDRESS: 0x0002
BIT(s)
4/5.2.15.0
OUI c:r
ADDRESS: 0x0003
BIT(s)
4/5.3.15:0
OUI c:r
Copyright © 2007–2009, Texas Instruments Incorporated
Table 2-19. XS_CONTROL_1
1 = XGXS reset (including all registers)
0 = Normal operation (Default)
1 = Enable loop back mode.
If the device is configured as PHY XS (PRTAD(0) = 0), then
XAUI_DATA_LOOPBACK will be performed (Same as SLOOP).
If the device is configured as DTE XS (PRTAD(0) = 1), then
XGMII_DATA_LOOPBACK will be performed (Same as PLOOP)
0 = Disable loop back mode (Default)
This bit always reads 1 indicating operation at 10 Gbps and above.
1 = Low power mode
0 = Normal operation (Default)
In low power mode all the internal clocks and datapaths are placed in shut
down mode. After de-assertion of this bit, datapath reset (4/5.32800.15)
needs to be performed to achieve proper datapath function. Serdes PLL's
can be shut down by de-asserting bits 4/5.36864.12 and 4/5.36864.4. Jitter
cleaner PLL can be shut down by de-asserting 4/5.37127.15
This bit always reads 1 indicating operation at 10Gbps and above.
These bits always read 0 indicating operation at 10Gbps.
Table 2-20. XS_STATUS_1
1 = Fault condition detected
(either on TX or RX side. This bit is OR ed version of 4/5.8.10 and 4/5.8.11)
0 = No fault condition detected
1 = XS Transmit link is up.
0 = XS Transmit links is down.
(This bit is latched low version of 4/5.24.12)
This bit always reads 1 indicating support for low power mode
Table 2-21. XS_DEVICE_IDENTIFIER_1
NAME
Organizationally unique identifier.
Table 2-22. XS_DEVICE_IDENTIFIER_2
NAME
Device identifier. Manufacturer model and revision number
Submit Documentation Feedback
Product Folder Link(s):
SLLS838F – MAY 2007 – REVISED DECEMBER 2009
(1)
DEFAULT: 0x2040
DESCRIPTION
DEFAULT: 0x0082
DESCRIPTION
DEFAULT: 0x4000
DESCRIPTION
DEFAULT: 0x50D0
DESCRIPTION
TLK3134
TLK3134
(2)
ACCESS
RW
SC
RW
RO
RW
RO
ACCESS
RO
RO/LL
RO
ACCESS
RO
ACCESS
RO
Detailed Description
51

Advertisement

Table of Contents
loading

Table of Contents