4.16 Mdio Timing Requirements Over Recommended Operating Conditions; Mdio Read/Write Timing; Hstl I/O Schematic - Texas Instruments TLK3134 Data Manual

4-channel multi-rate transceiver
Hide thumbs Also See for TLK3134:
Table of Contents

Advertisement

TLK3134
SLLS838F – MAY 2007 – REVISED DECEMBER 2009

4.16 MDIO Timing Requirements Over Recommended Operating Conditions

PARAMETER
t
MDC period
period
t
MDIO setup to ↑ MDC
setup
t
MDIO hold to ↑ MDC
hold
T
MDIO valid from MDC ↑
valid
(1) Unless otherwise noted.
MDC
MDIO
50 W
OUTPUT
124
Electrical Specifications
TEST CONDITIONS
See
Figure
4-13.
See
Figure
4-13.
See
Figure
4-13.
t
PERIOD
t
SETUP
Figure 4-13. MDIO Read/Write Timing
50
W
transmission line
VDDQ
GND
PCB
Figure 4-14. HSTL I/O Schematic
Submit Documentation Feedback
Product Folder Link(s):
MIN
100
10
10
0
t
HOLD
VDDQ
150/200/
300/Open
( )
W
150/200/
300/Open
( )
W
GND
R W
VREF
R W
INPUT
Copyright © 2007–2009, Texas Instruments Incorporated
TLK3134
www.ti.com
(1)
NOM
MAX
UNIT
ns
ns
ns
40
ns
+
-

Advertisement

Table of Contents
loading

Table of Contents