Recommended Equipment

P1
Vcc 1
Input
J4
Pattern to
D
Driver
GND 1
Figure 9. EVM Configuration for Inducing a Ground Potential Difference Voltage Between Nodes
2
Recommended Equipment
5-Vdc at 0.5 A power supply
A pattern generator capable of supplying single-ended signals at the desired signaling rate and input
levels
A multiple-channel, high-bandwidth oscilloscope, preferably above the 100-MHz range. Differential and
single-ended oscilloscope probes
When using two or more EVMs, a 100-Ω transmission medium between transceivers (twisted-pair
cable recommended, CAT5 cable for example) made be used using JMP7 and JMP9 (half duplex)
between EVMs. Full-duplex connections can be made using JMP5/JMP7 and JMP8/JMP9. The
termination resistors need to be configured for each case.
2.1
EVM Configurations
The schematic for the ISO1176TEVM appears on the last page of this manual.
Table 1
contains a list of the onboard jumpers and their function as well as the input and output loading
installed on the board for the half-duplex ISO1176TEVM.
full-duplex ISO35TEVM and ISO3086TEVM.
Jumper Function
DATA/CONTROL
SIDE JUMPERS
JMP1 – Receiver Output
JMP2 – Receiver Enable
JMP3 – Driver Enable
JMP4 – Driver Input
JMP6 – D1/D2 Test Point
JMP16 – Rout Load
(1)
These resistors are provided as impedance-matching terminations to be used when driving these
signals with 50-Ω source impedance test/measurement equipment. When not driving these signals with
a 50-Ω source, the components must be removed.
8
ISO1176T/35T/3086T Evaluation Module
P3
Vcc 2
Interconnecting media
J8
A
EVM #1
B
J9
GND 2
P3
Power Supply
Power Supply
No . 1
Table 1. EVM Configuration Options for ISO1176T
Configuration
Jumper short allows Rout to be
pulled up to Vcc or to GND through
a 1-kΩ resistor.
Copyright © 2010, Texas Instruments Incorporated
P3
Vcc 2
A
J8
EVM #2
B
J9
GND 2
Power Supply
No . 3
No . 2
Table 2
contains the same information for the
I/O Load
R1 (see JMP16)
R2 – 50 Ω
R3 – 50 Ω
R4 – 50 Ω
R7 – Uninstalled
R8 – Uninstalled
R10 – Uninstalled
SLLU122A – April 2010 – Revised July 2010
www.ti.com
P1
Vcc 1
Output from
R
Receiver
GND 1
(1)
(1)
(1)